HIT-RE 500 V4 Epoxy anchor
New productItem #r12560055
Ultimate-performance injectable epoxy mortar with approvals for rebar connections and heavy-duty anchoring
- Approvals / test reports: ETA, Fire
- Seismic loading: Yes
- Fatigue loading: Yes
Share
Features
- Ultimate performance and model code-compliant design for virtually any concrete-to-concrete and steel-to-concrete connections – ETA assessment for anchoring inc. C1 and C2 seismic and ETA for rebar inc. fire and seismic
- The first epoxy mortar qualified according to EAD 332402-00-0601 for concrete-to-concrete connections – rigid connections can now be designed and executed with post-installed rebars without splices according to the newest design method TR069
- Suitable for the toughest jobsite conditions – works even in diamond-cored, wet or underwater holes (depending on rod specification and approvals), extremely deep injections, large diameters and at temperatures down to -5°C / 23°F
- Improved bond strength in the most demanding applications – such as cracked concrete and seismic C2 conditions
- Easier to specify and order – use PROFIS Engineering to design baseplate connections and PROFIS Rebar to design concrete-to-concrete connections according to EC2, TR069 or the Hilti Design Method
Applications
- Structural connections with post-installed rebar (e.g. slab extensions, wall/column connections, stairs, foundations, etc.)
- Structural renovation of buildings, bridges and other civil works, retrofitting and re-strengthening of concrete members
- Anchoring structural steel connections (e.g. steel columns, beams, etc.)
- Fastening structural baseplates, including in cracked concrete and challenging seismic conditions
- Fastening in natural stone and wood, including GLT and CLT made from spruce, pine or fir

For approval or certificate information, please see individual items.
Technical Data
Documents
-
- ETA-20/0475 HCC-K, English, German, Polish, French, [ 3.8 MB ]
- ETA-20/0697 HCC-U, English, German, French, [ 14.9 MB ]
- ETA-20/0541_HIT-RE 500 V4_Anchor_EC2_100years_112021, English, German, Polish, French, [ 8.9 MB ]
- ETA-20/0793_HIT-RE 500 V4_Rebar_EC2_Seismic_112020, English, French, [ 6.9 MB ]
- ETA-23/0277 HAS-U A4 Fatigue, English, German, [ 3.9 MB ]
- ETA-20/0539_HIT-RE 500 V4_07/022, English, German, French, Polish, [ 3.7 MB ]
- ETA-20/0540_HIT-RE 500 V4_Rebar_EC2_100years_112020, English, German, French, Polish, [ 11.5 MB ]
-
- Operating Instruction HIT-RE 500 V4 RoW, Italian, German, Russia, Turkish, Swedish, Arabic, French, Portuguese, Spanish, Malay, Thai, Finish, Norwegian, Polish, Lithuanian, Latvian, Romanian, Korean, Bulgarian, Slovakian, Japanese, Estonian, Croatian, English, Chinese, Danish, Czech, Hungarian, Dutch, Greek, Slovene, [ 13.1 MB ]
-
- Technical data sheet for HIT-RE 500 V4 injectable mortar in concrete, English, [ 918.5 kB ]
- Technical data sheet for HIT-RE 500 V4 injectable mortar in Steel to Concrete, English, [ 722.2 kB ]
- Concrete-to-Concrete Handbook for EU framework, English, [ 18.7 MB ]
- Whitepaper SOFA W4607: Improved design for anchors undershear loading, English, [ 1.8 MB ]
- TR 066 White paper W4595 (EN), English, [ 2.3 MB ]